FacebookLinkedInWhatsApp
EPS Series — EPS Emergency Lighting Power Supply
三一电源注册商标

EPS Series

EPS Emergency Lighting Power Supply

Sanyi Power EPS DC backup supply catalogue retains the 43, 53 and 63 series documents. Verified 43/53 versions provide 13.5V or 27V load outputs, automatic mains/battery selection and float charging. Confirm the 63100 parameters and document revision before selection.

Certifications

Verify applicable certification and coverage for the exact model
EPS power supplyEPS emergency power supplyEmergency lighting power43 Series EPS53 Series EPS63 Series EPS

Available Models

EPS-SD-4301PDF
EPS-SP-4303PDF
EPS-SP-5303PDF
EPS-ST-4304PDF
EPS-ST-4308PDF
EPS-ST-4310PDF
EPS-ST-5304PDF
EPS-ST-5308PDF
EPS-ST-5310PDF
EPS-ST-63100PDF

Inquire About This Product

Need custom parameters or bulk pricing? Contact us for a tailored solution.

Inquire About This Product →

Features

  • Automatic mains/battery selection
  • Battery float charging
  • Multiple model and circuit options
  • LED power indicator

Specifications

Available ModelsEPS-SD-4301 / EPS-SP-4303 / EPS-SP-5303 / EPS-ST-4304~5310 / EPS-ST-63100
Input Voltage100–240Vac, 50/60Hz (verified 43/53 models)
Output Voltage13.5Vdc / 27Vdc (43/53 voltage versions; 63100 pending verification)
Transfer TimeAutomatic selection; confirm timing by model and load. Hold-up time is not transfer time.
ProtectionCheck overload, short-circuit, charging overvoltage and undervoltage protection by model

EPS DC backup supplies for access control and security

This catalogue retains all 43, 53 and 63 Series documents. The verified 43/53 range uses 13.5V or 27V load outputs with float charging and automatic mains/battery selection. These low-voltage DC supplies are not interchangeable by name with high-power building AC EPS systems. Check allowable device voltage, circuits, load and battery runtime for the exact model.

What to confirm before selecting an EPS supply

  1. 1

    Define the load and output

    Identify the emergency-lighting, security or other load, then confirm AC or DC output, voltage and total load.

  2. 2

    Choose the model and circuits

    The catalogue includes SD, SP and ST constructions with different circuit counts. Select from wiring and maintenance needs, not from the series number alone.

  3. 3

    Check transfer and backup

    Hold-up time is not mains/battery transfer time. Verify transfer performance for the exact model and load. Runtime also depends on battery capacity, condition, wiring losses and temperature.

  4. 4

    Verify the datasheet

    Download the exact PDF and check wiring, dimensions, environment, protection and project requirements before ordering.

EPS models listed on this website

SD / SP
EPS-SD-4301, EPS-SP-4303, EPS-SP-5303
ST 43 Series
EPS-ST-4304, EPS-ST-4308, EPS-ST-4310
ST 53 Series
EPS-ST-5304, EPS-ST-5308, EPS-ST-5310
ST 63 Series
EPS-ST-63100 (verify parameters and document revision first)
43/53 input
100–240Vac, 50/60Hz; verify the exact model datasheet
43/53 load output
13.5Vdc or 27Vdc versions; verify the battery-charging channel separately
Transfer and hold-up
Automatic mains/battery selection; 50ms typical hold-up at 220Vac full load is not a transfer-time specification

Information to send for selection

  • Load type, quantity, startup and steady power
  • Input/output voltage and AC or DC form
  • Number of circuits, mounting and space limits
  • Battery, target runtime and ambient temperature

EPS power supply FAQ

Which EPS models are currently listed?

The website lists EPS-SD-4301, EPS-SP-4303, EPS-SP-5303, EPS-ST-4304/4308/4310, EPS-ST-5304/5308/5310 and EPS-ST-63100.

Are an EPS supply and a UPS the same?

No. Output form, transfer method, load profile and system purpose may differ. They cannot be substituted by name alone.

How do I choose between the 43, 53 and 63 series?

Compare output form, circuit count, load and installation requirements in the exact datasheet. The series number alone is not a specification.

How is EPS backup runtime calculated?

Runtime depends on load, battery voltage and capacity, conversion efficiency, wiring loss, battery condition and temperature.

Is the 50ms hold-up time the battery transfer time?

No. The verified 43/53 datasheets list 50ms typical hold-up at 220Vac full load and describe automatic mains/battery selection, but do not provide a uniform numeric transfer guarantee. Verify continuity with the actual load.

Open the dedicated 43 Series EPS guide →
Inquire About This Product