Which EPS models are currently listed?
The website lists EPS-SD-4301, EPS-SP-4303, EPS-SP-5303, EPS-ST-4304/4308/4310, EPS-ST-5304/5308/5310 and EPS-ST-63100.

EPS Series
Sanyi Power EPS DC backup supply catalogue retains the 43, 53 and 63 series documents. Verified 43/53 versions provide 13.5V or 27V load outputs, automatic mains/battery selection and float charging. Confirm the 63100 parameters and document revision before selection.
Need custom parameters or bulk pricing? Contact us for a tailored solution.
Inquire About This Product →| Available Models | EPS-SD-4301 / EPS-SP-4303 / EPS-SP-5303 / EPS-ST-4304~5310 / EPS-ST-63100 |
| Input Voltage | 100–240Vac, 50/60Hz (verified 43/53 models) |
| Output Voltage | 13.5Vdc / 27Vdc (43/53 voltage versions; 63100 pending verification) |
| Transfer Time | Automatic selection; confirm timing by model and load. Hold-up time is not transfer time. |
| Protection | Check overload, short-circuit, charging overvoltage and undervoltage protection by model |
This catalogue retains all 43, 53 and 63 Series documents. The verified 43/53 range uses 13.5V or 27V load outputs with float charging and automatic mains/battery selection. These low-voltage DC supplies are not interchangeable by name with high-power building AC EPS systems. Check allowable device voltage, circuits, load and battery runtime for the exact model.
Identify the emergency-lighting, security or other load, then confirm AC or DC output, voltage and total load.
The catalogue includes SD, SP and ST constructions with different circuit counts. Select from wiring and maintenance needs, not from the series number alone.
Hold-up time is not mains/battery transfer time. Verify transfer performance for the exact model and load. Runtime also depends on battery capacity, condition, wiring losses and temperature.
Download the exact PDF and check wiring, dimensions, environment, protection and project requirements before ordering.
The website lists EPS-SD-4301, EPS-SP-4303, EPS-SP-5303, EPS-ST-4304/4308/4310, EPS-ST-5304/5308/5310 and EPS-ST-63100.
No. Output form, transfer method, load profile and system purpose may differ. They cannot be substituted by name alone.
Compare output form, circuit count, load and installation requirements in the exact datasheet. The series number alone is not a specification.
Runtime depends on load, battery voltage and capacity, conversion efficiency, wiring loss, battery condition and temperature.
No. The verified 43/53 datasheets list 50ms typical hold-up at 220Vac full load and describe automatic mains/battery selection, but do not provide a uniform numeric transfer guarantee. Verify continuity with the actual load.
2026-09-16
A datasheet-based guide to mains/battery transfer, 13.5V/27V float charging, wiring checks and commissioning for EPS-SD-4301, EPS-SP-4303, EPS-ST-4304, EPS-ST-4308 and EPS-ST-4310.
2026-09-14
A practical 43 Series EPS selection guide for emergency lighting and security backup projects: 12V/24V systems, 1–10 outputs, load current, battery sizing and mains/battery transfer requirements.
2026-04-24
A facility-focused comparison of EPS (Emergency Power Supply) and UPS (Uninterruptible Power Supply) for emergency lighting, fire-safety loads, and critical IT — covering code requirements, runtime, transfer time, sizing, and how to avoid specifying the wrong system.